72602
OWNER’S MANUAL
READ ALL INSTRUCTIONS AND WARNINGS IN THIS MANUAL BEFORE USING THIS SIGHT
CenterPoint Precision Optics
7629 Routes 5 & 20
Bloomeld, NY 14469
United States of America
www.centerpointoptics.com
1-866-726-1122 72602-515
Made in China
BUYER AND USER HAVE THE DUTY TO OBEY ALL LAWS
ABOUT THE USE AND OWNERSHIP OF THIS SIGHT.
All CenterPoint™ scopes are constructed with high quality precision machined parts. The rugged
one piece tube construction works for all terrains and weather. The scope is precision machined to
exact tolerances from aircraft-grade aluminum alloy.
Direct viewing of the sun can cause permanent eye damage. Do not attempt to
view the sun through this riescope or any other optical instrument.
Always follow all rules of rearm and gun safety.
This product contains a chemical known to the state of California to cause
cancer and birth defects (and other reproductive harm).
Learning the parts of your scope
Learning the names of the parts of your new sight will help you to understand your owner’s manual.
1. Ocular lens
2. Elevation (vertical) adjustment
3. Red/Green illumination dial
4. Multi-Reticle Dial
5. Objective lens
6. Removable- ip open lens covers
7. Windage (horizontal) adjustment
8. Weaver-style mounting rings
Mounting Procedure
CAUTION: Always ensure your rie is UNLOADED, UNCOCKED and the
safety is applied before tting the scope. Practice safe handling proce-
dures at all times.
1. Locate the proper mounting position on your rie
2. Loosen the mounting screws (A and B) from the ring mount
3. Install and adjust the scope at a proper position to suit your shoot-
ing preferences, then tighten the mounting screws
4. To adjust the position of the scope within the mount; loosen screws
C and D. Once the scope is at a proper position, tighten the screws
on the ring to ensure a rm grip on the scope
NOTE: Do not over tighten the screws as you could cause damage to the scope body.
The scope is now ready to be zeroed.
Scope Adjustment
The purpose of zeroing the scope is to ensure that the scope is
aligned with the impact point of the bullet. Before zeroing the scope,
read the following adjustment instructions carefully.
1. Place a target 100 yards away
2. Ideally use a steadying device such as a bipod or shooting
stand, aim at the center of the target and re a test shot, if safe
to do so
3. If the impact point of the bullet is exactly in the center of the
target then the scope is zeroed. If it is not, you will need to
adjust the reticle using the elevation and/or windage adjustments
4. Remove the caps from the windage and elevation dials
5. Vertical Adjustment (Elevation) - Use tools to turn the adjusting knob as required. One click in
either direction equals 1 MOA
6. Horizontal Adjustment (Windage) - Use your TOOLS to rotate the adjusting knob as required.
One click in either direction equals 1 MOA
7. Having adjusted the windage and elevation as required, re, if safe to do so, another test shot.
Keep adjusting and test ring until the test shot impacts on the center of the target when the
reticle is on the center of the target. This is vital for accurate shooting
8. Once the scope is zeroed, be sure to put the windage and elevation caps back on
9. Adjustments may need to be made after changing reticles
Red or Green Dot
1. Remove the battery cover from the red/green illumination
dial by turning the cover counter clockwise while holding the
sides of the illumination dial
2. Install one CR2032 3V lithium battery into the compartment
with the “+” side up
3. Replace the cover and tighten in by turning it clockwise, while
holding the sides of the illumination dial
4. Turn the red/green illumination dial to illuminate the red or
green dot. The brightness will change as you turn the dial.
The markings on the dial show the color and intensity of
the light. Lining the “R” or “G” up with the dot will turn the
illumination off
Selecting Reticle
1. Rotate the multi-reticle dial to the desired reticle, making sure to align
the dial with the indexing mark.
Maintenance
Take care not to drop or knock the scope once it is zeroed.
Keep the protective lens covers in place when the scope is not being
used.
Store the scope in a cool dry place when not in use.
Be careful to avoid contact with acid, alkaline or corrosive chemicals.
Do not attempt to lubricate any part of the scope.
Do not disassemble the scope. Do not loosen or remove any screws or
parts. Any such or similar actions will void the warranty.
C D
A B
Wipe the lens with a clean annel cloth to keep it clean and dry. Do not use nger or nger nail to
touch or clean lenses.
Use only a clean annel cloth for cleaning.
To maintain battery life, turn illumination off when not in use.
For extended storage, remove the battery
Specications
Model
72602
Magnication
1x
Objective Diameter (mm)
30
Eye Relief (inches)
Innite
Field of View (@ 100yds)
33’
Tube Diameter (mm)
30
Length (inches)
5.83”
Weight (ounces)
6.49
W/E Adjust Click Value
1 MOA
Batteries
1: CR2032 3V Lithium
LIMITED LIFETIME WARRANTY ON CENTERPOINT SCOPES
Your CenterPoint™ scope is warranted to be free of defects in materials and workmanship for the
lifetime of the original owner. This warranty does not cover damages due to fair wear and tear,
failure to provide routine maintenance, and does not include batteries or accessories. This war-
ranty lasts as long as the original purchaser owns the product, and is not transferable. In the event
of a defect under this warranty, we will, at our option, repair or replace the product provided our
inspection indicates that an original defect exists. CenterPoint reserves the right to replace any
product which is no longer available with a product of comparable value and function. If Center-
Point determines the repair is not covered under the warranty guidelines, there could be a charge
to you for the repair. This is a limited warranty and does not cover damages caused by misuse,
improper handling or installation or maintenance provided by someone other than CenterPoint.
This limited warranty does not include consequential damages, incidental damages, or incidental
expenses, including damage to property or any other expense. CenterPoint disclaims any implied
warranties. Some states do not allow the exclusion or limitation of incidental or consequential
damages, or allow limitations on implied warranties so the above limitations or exclusions may
not apply to you. This warranty gives you specic legal rights, and you may also have other rights
which vary from state to state and country to country.
WARRANTY CLAIMS/ REPAIR SERVICE
If your scope needs repair, call CenterPoint Customer Service at 1-800-726-1122 or visit our web
site at www.centerpointoptics.com DO NOT ATTEMPT TO DISASSEMBLE IT! Any disassembly or
modication not performed by CenterPoint Precision Optics will void the warranty.
USA Customers: Please contact CenterPoint before shipping your product. Include with product
your name, address, description of problem, phone number and copies of sales receipt and war-
ranty. A check or money order in the amount of $10.00 to cover the cost of postage and handling
is also required. Package and return to CenterPoint, Crosman Corporation, 7629 Rts. 5 & 20,
Bloomeld, NY 14469. CenterPoint will not assume any responsibility for any loss or damage
incurred in shipping.
International Customers: Please return product to your nearest distributor. If you do not know
your distributor, please call 585-657-6161 and ask for our International Department for assistance.
Shipping and handling costs may apply.
Vedere la pagina 0
1 2 3

Sommario

Pagina 1 - OWNER’S MANUAL

72602OWNER’S MANUALREAD ALL INSTRUCTIONS AND WARNINGS IN THIS MANUAL BEFORE USING THIS SIGHTCenterPoint Precision Optics7629 Routes 5 & 20Bloomel

Pagina 2 - MANUAL DEL PROPIETARIO

EspecicacionesModelo72602Aumento1xDiámetro del objetivo (mm)30Distancia ocular (pulgadas)InnitoCampo visual (a 100 yd)33’Diámetro del tubo (mm)30Lo

Pagina 3 - MANUEL D’UTILISATION

CaractéristiquesModèle72602Grossissement1xDiamètre de l’objectif (mm)30Dégagement oculaire (cm/pouces)InnitoChamps de vision (@ 100 mètres)33’Diamètr

Commenti su questo manuale

Nessun commento